1 | Conduit cutters
Conduit cutters for plain cuts.

,Duct-pipe-calibration-set,Duct-pipe-pressure-test,Mini-transmitters,Cable-cutting-tongs,Pipe-test-bladder,Shuttoff-bladder,Conduit-duct-saw,Système-calibrage-conduit-tube,Test-d'étanchéité-conduit-tube,Cisaille-coupe-conduit-tube,Membrane-test,Cortadores-conductos-tubos,Membran-a-testar-conductos-tubos,Test-de-estanqueidad,Cierre-conductos-tubos,Scie-circular-conductos-tubos
,,,
,,,
,,,
CodeTypeD-OD Length kg
273171 MRS 43to 42 215 0,45
273172 MRS 50to 50 265 0,60
273173 MRS 63to 63 285 0,70
273174 MRS 75to 75 485 1,60
2 | Burring tools
Burring tools for in- and outside of plastic conduits.

Paring knife MSM 40, for separating multiple conduits.
,,,
,,,
,,,
CodeTypeD-OD Burring Mat. kg
273185 MRA 6320-63 only extern Poly. 0,25
273180 MRE 5028-50 ext. /intern Alu 0,43
273200 MSM 40Paring knife --- Steel 0,50
3 | Conduit and cable slitter
Conduit slitter for lengthwise and circumferential slitting of plastic conduits and cable covers. Complete reinforced steel version. In case 195x75x45 mm.

,,,
,,,
CodeTypeTo wall thickn. L/W/H mm kg
255905 KMS 66 195x75x45 0,35
255910 ERM 6Spare knife --- 0,03
4 | Cable conduit saw
This cable conduit saw SRS 6.1 is a further development of the proven SRS 6. The saw is suitable for cutting occupied and unoccupied cable conduits without damaging internal cables or subducts. The saw is suitable for conduits at an outer diameter of 32-150 mm and at a max. wall thickness up to 6 mm. The saw can precisely cut lengthwise and crosswise and can also precisely cut windows into the cable conduit. Especially for long cuts on the cable conduits which are necessary for cable line redirections the great benefits of this saw pay off.

The cutting depth can be precisely adjusted to a 1/10 of a millimetre by an adjustment mechanism thus the cables inside the cable conduit are well-protected. The cutting depth has always to be set 0,2 mm less than the conduits wall thickness. The remaining very thin plastic membrane will be removed by a lifter tool thus the cable is also protected during this final step.
 
The conduit guiding plates allow a high safety at work as well as accurate cuts. The guiding plates are available for the below mentioned conduit-diameters. The cordless saw is handy and small in order to be fit for application also in narrow working conditions its weight is below 2 kg. Included in delivery are the following parts:
  • Accu-saw with high-quality blade hard metal equipped and 3 accus with 1 charger
  • Precise pre-adjustment of the cutting depth, 1/10 mm accurate sliding calliper.
  • Lifter for the window-cutting rest
  • Packed and delivered in robust box, 445x355x255, weight app. 6,5 kg
  • Only approx. 1,9 kg of weight for comfortable application
,,,
,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeDevice For D-OD kg
273212 SRS 6.1Saw as above 32-150 6,50
273228 RFP 32Guide plate 32 0,35
273230 RFP 40Guide plate 40 0,32
273232 RFP 50Guide plate 50 0,26
273234 RFP 63Guide plate 63 0,26
273237 RFP 64+Guide plate 64-150 0,20
273222 ESB 6Spare blade --- 0,03
5 | Lubricant for FOC
Jettinglube lubricant for blowing-in fibre optic cables. Excellent lubricating effect. Adheres to the duct wall and leaves the cable nearly dry, an advantage for over blowing and working in cascades with further blowing machines. Consumption approx. 0,5 l per 1000 m at duct-ID 40 mm. For other duct-ID analogue

For lubrication unique and ultimate classification, Water pollution class - non-hazardous, acc. to VCI-Conception. Safety data sheets are available.
,,,
,,,
,,,
CodeTypePack. drums kg
234960 CJL 10321 bottle 0,95 l 1,00
234965 CJL 103212 bottles 0,95 l 12,00
234970 CJL 3784 bottles 3,80 l 16,00
6 | Lubricant liquid
Cable lubricant Softenol, liquid, for blowing-in and for pulling-in fibre optic cables.

For lubrication unique and ultimate classification, Water pollution class - non-hazardous, acc. to VCI-Conception. Safety data sheets are available.
,,,
,,,
,,,
,,,
CodeTypePack. drums kg
235800 SOF 051 canister 5 l 5,60
235810 SOF 101 canister 10 l 11,00
235830 SOF 251 canister 25 l 26,50
235890 SOF 1901 barrel 190 l 200,00
7 | Duct cleaning sponge
Sponge for duct cleaning and pre-lubricating prior to cable blowing

,,,
,,,
,,,
,,,
CodeTypeD-OD D-ID Cellular Qty. kg
275408 RSM 2832 28 D 45x90 1 pcs. 0,01
275410 RSM 3540 35 D 55x90 1 pcs. 0,01
275412 RSM 4050 40 D 65x90 1 pcs. 0,01
275414 RSM 5163 51 D 78x90 1 pcs. 0,02
8 | High pressure test
The new pressure test device combines three test methods in one electronic device. General test rules” individual selectable acc. requirements from the customer - The requirement from Deutsche Telekom acc. “ZTV-TKNETZ 40” - The low-pressure test acc. EN 1610:2015 as well as worksheet DWA-A-139:2009

The high-pressure test is presently the most frequent test method in the range of pressure tests for protective ducts. This test method will be performed at thick-walled protective ducts and subducts (micro ducts). With regards to the protective ducts, ducts with OD 50/40/32 mm are most frequently used application. For subducts a wider range of ducts can be tested from 7x1,5 until 20x2,5 mm. The high-pressure test distinguish between two different targets:
  • Verification of optimal blowing-in performance, which is guaranteed only by a pressure-tight duct system (short-term target)
  • Assurance of pressure-tight duct, the joints and connectors against water intrusion and the subsequent intrusion of soiling with sand. This results in incrustations, which causes problems during the blowing-in process and possibly later at blowing-out of cables (long-term target)
,,,
CodeTypeExplanation kg
231700 High pressureSee the following devices 0,00
9 | High and low air pressure testing devices
The DPG 17U Universal pressure test device for test of cable ducts with regards to protective ducts and subducts working in the range of 0…7 bar. The operation is made by a 7” colour-graphic-touch display. The new device support the user through a simple and menu-driven operation. With the help of a matrix (table) three different test methods can be selected. Those are “General test rules” individual selectable acc. requirements from the customer, the requirement from Deutsche Telekom acc. “ZTV-TKNETZ 40” and the low-pressure test acc. “EN 1610:2015”. This results in a maximum support for the user.

The result of the pressure test is summarized in a clear test protocol with three core areas. The test protocol will be stored on the device and can be loaded by a USB-interface to a customary PC. ?
The left shown 1. protocol shows a passed test “Test criteria fulfilled” ?
The left shown 2. protocol shows a failed test “Test criteria not fulfilled”
  • Upper area: General data like: Contracting company with name of operator, construction site, duct, temperature, times, measurement data with calibration status
  • Middle area: Result of the pressure test through colour-marked message: “Test criteria fulfilled” or “Test criteria not fulfilled”
  • Lower area: Graph with the two phases settling time and main test
,,,
CodeTypeDesignation Press. Application kg
231740 DPG 17UUniversal pressure test device 0-7 bar Cable conduits 6,40
10 | High air pressure testing NE2 and NE3
Pressure test distribution units for high-pressure tests of 1 duct OD 7 to 110 mm for protective ducts and subducts (micro ducts).

With regards to the protective ducts the 50x4.6 duct is the most frequently used application. For subducts a wider range of ducts can be tested from 7x1.5 until 20x2.5 mm. For the connection of the ducts the right accessories have to be used to perform the test.

,,,
CodeTypeDesignation Port Press. kg
23163007 DPV 1Pressure test distribution unit 1 0-10 bar 11,30
11 | High air pressure testing NE2 and NE3
Pressure test distribution units for high-pressure tests of ducts OD 20 to 110 mm, for 4 protective ducts or 4 subducts (micro ducts).

With regards to the protective ducts the 50x4.6 duct is the most frequently used application. For subducts the dimension 20x2.5 mm can be tested. For the connection of the ducts the right accessories have to be used to perform the test.

,,,
CodeTypeDesignation Port Press. kg
2316293 DPV 4Pressure test distribution unit 4 0-10 bar 43,00
12 | High air pressure testing NE3
Pressure test distribution units for high-pressure tests of 1-12 subducts (micro ducts).

A wider range of subducts can be tested from 7x1.5 until 20x2.5 mm. For the connection of the ducts the right accessories have to be used to perform the test.

,,,
CodeTypeDesignation Port Press. kg
231680 DPV 12Pressure test distribution unit 12 0-7 bar 52,00
13 | Reducing coupling for high pressure test
Reducing coupling D 10-7, with duct 10x2/100, for D-OD 7 mm, for coupling subduct OD 7 mm with pressure test distribution units DPV 12, necessary to order 275750 DAK 10.

,,,
CodeTypeD-OD Press. kg
231686 AKR 077 mm 0-7 bar 0,02
14 | Air connectors for calibration sets
Air connectors for subduct calibration sets and for high pressure test units.

,,,
,,,
,,,
,,,
CodeTypeD-OD Press. kg
275750 DAK 1010 mm 0-7 bar 0,39
275752 DAK 1212 mm 0-7 bar 0,41
275754 DAK 1414 mm 0-7 bar 0,40
275756 DAK 1616 mm 0-7 bar 0,40
15 | Conduit plug for duct-OD
Conduit plug for fixing on duct-OD with hose safety coupling applicable for duct calibration, duct pressure tests, duct cleaning etc.

,,,
,,,
CodeTypeD-OD Press. kg
2316512 KRA 2020 mm 0-7 bar 0,40
23165140 KRA 2525 mm 0-7 bar 0,46
16 | Connection coupling
Connection coupling for subducts, made of steel, plug-in type, for distribution device DPV 12

,,,
,,,
,,,
,,,
,,,
CodeTypeFor subduct To device Max. Press. kg
231690 AKS 10D 10 mm DPV 12 0-7 bar 0,13
231691 AKS 12D 12 mm DPV 13 0-7 bar 0,13
231692 AKS 14D 14 mm DPV 14 0-7 bar 0,14
231693 AKS 16D 16 mm DPV 15 0-7 bar 0,15
231694 AKS 20D 20 mm DPV 16 0-7 bar 0,21
17 | Duct plug
Duct plug of plastic , 0-7 bar, for subducts D 5-20 mm

,,,
,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeFor subduct Max. Press. kg
272552 ESM 05D 5 mm 0-7 bar 0,03
272556 ESM 07D 7 mm 0-7 bar 0,01
272560 ESM 10D 10 mm 0-7 bar 0,01
272562 ESM 12D 12 mm 0-7 bar 0,02
272564 ESM 14D 14 mm 0-7 bar 0,03
272568 ESM 16D 16 mm 0-7 bar 0,02
272572 ESM 20D 20 mm 0-7 bar 0,02
18 | Test manometer for conduits
Testing manometer 10 bar, as end section of cable conduits, for high pressure tests, with safety coupling 42 mm. For air distribution devices DPV 1 + DPV 4. Max. air pressure 7 bar. To apply with conduit plugs KRA 20-110.

,,,
CodeTypeFor Together with Max. Press. kg
231633 PMK 10DPV 1+DPV 4 KRA 20-110 0-7 bar 0,70
19 | Test manometer for subducts
Testing manometer 10 bar, as end section of subducts for high pressure tests, with safety coupling NW 7,4. For air distribution devices DPV 12. Max. air pressure 7 bar. To apply with conduit plugs AKS 10-20.

,,,
CodeTypeFor Together with Max. Press. kg
231696 PME 10DPV 12 AKS 10-20 0-7 bar 0,41
20 | Case for accessory
Case for accessory of high pressure test devices, without parts, with 12 shelves as following:
  • 10 cases each 132x82x105 mm
  • 1 case of 168x131x105 mm
  • 1 case of 286x168x105 mm
,,,
CodeTypeDimension kg
231698 KZD 6040600x400x155 mm 4,35
21 | Duct calibration set
Conduit calibration and leakage-test unit. Calibration and leakage-test before starting the cable blowing-in procedure is the safest guarantee for successful installation of fibre optic cables. Unit consisting of:
  • Compressed air regulator with adjustable tripod.
  • 5 m high pressure hose, calibre D 35, transmitter, for duct-D 50x4,6.
  • All other diam. of calibres are available, please see extensions below.
  • With conduit plug and catch box for the piston.
  • With electronic detector 33 kHz . Compl. set in alu-case 780x380x330.
  • Max. pressure setting 2-3 bar.
,Duct-pipe-calibration-set,Duct-pipe-pressure-test,Système-calibrage-conduit-tube,Test-d'étanchéité-conduit-tube,Calibración-conductos-tubos,Comprobación-de-impresión,Estanqueidad-conductos-tubos
CodeTypeD-ID kg
231601 RKV 4040-41 mm 27,00
22 | Calibre extension set
Supplementary extension set for calibration and leakage test unit.

,,,
,,,
CodeTypeD-ID kg
231602 RKVE 3333-34 mm 2,60
231603 RKVE 2727-28 mm 2,00
23 | Calibre housings
Calibre housings of polyamide with sleeve rings, without transmitter. Calibre length 145 mm, total length 250 mm

,,,
,,,
,,,
,,,
CodeTypeCalibre D/L/total Air max. D-ID kg
231644 MKV 4545/145/250 2-3 bar 51-52 0,45
231646 MKV 3535/145/250 2-3 bar 40-41 0,36
2316475 MKV 2828/145/250 2-3 bar 33-34 0,29
231648 MKV 2525/145/250 2-3 bar 27-28 0,32
24 | Miniature transmitter D 18 mm
Miniature transmitter D 18x88 mm, incl. battery, suitable for all a. m. calibres.

,,,
,,,
CodeTypeD/L Frequ. Thread Depth Cap. kg
231621 SKS 18N18/88 33 kHz M 10 8,0 m 20 h 0,23
097300307 Spare-Battery 3,6V -- -- 20h 0,01
25 | Piston for loosing cables
Pistons for loosing old cables in ducts before blowing or pulling them out.

,,,
,,,
CodeTypeD-OD D-ID C-D kg
275230 LKO 4040 33-35 10-21 0,10
275232 LKO 5050 40-42 10-21 0,10
26 | Conduit plug for duct-OD
Conduit plug for fixing on duct-OD with hose safety coupling applicable for duct calibration, duct pressure tests, duct cleaning etc.

,,,
,,,
,,,
,,,
,,,
CodeTypeD-OD Press. kg
2316513 KRA 3232 0-7 bar 0,50
231651 KRA 4040 0-7 bar 0,84
231650 KRA 5050 0-7 bar 0,90
231649 KRA 6363 0-7 bar 1,00
2316541 KRA 110110 0-7 bar 3,20
27 | Sealing plug
Conduit sealing plug applicable for duct pressure tests.

,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeD-OD Press. kg
273569 ENSA 2020 0-7 bar 0,07
273572 ENSA 3232 0-7 bar 0,10
273575 ENSA 4040 0-7 bar 0,23
273580 ENSA 5050 0-7 bar 0,29
273585 ENSA 6363 0-7 bar 0,40
273586 ENSA 110110 0-7 bar 1,93
28 | Shut-off bladder Mini
Shut-off bladders to lock off the pipeline to be tested. Shut-off bladders are used on the opposite side of the test location. The short dimensions of the Mini version allow space-saving installation of pipe bends also.

,,,
,,,
,,,
CodeTypeFor pipe-ID Cyl.-D Cyl.-L Total-L kg
231768 SBM 7/1070-100 68 130 175 0,40
231770 SBM 8/1580-150 72 120 170 0,40
231772 SBM 12/20125-200 115 150 195 0,80
29 | Test bladder Mini
Test bladders Mini for testing and shutting off pipes for low pressure testing.

Air coupling (brass) standard for bladder extension. Air coupling (chromed) special CE-standard 10.4 mm, for inflating the duct.
,,,
,,,
,,,
,,,
CodeTypeFor pipe-ID Cyl.-D Cyl.-L Total-L kg
231776 PBM 4/0740-70 38 155 215 0,40
231778 PBM 7/1070-100 68 190 340 1,10
231780 PBM 10/15100-150 90 150 300 1,33
231782 PBM 15/20150-200 145 195 345 2,83
30 | Foot pump with double stroke
Foot pump with double stroke and safety valve 2.5 bar to inflate SBM shut-off bladders and PBM test bladders. The use of a second foot pump for the second pipe end saves considerable installation time.

,,,
CodeTypePress. kg
231786 FP 2.52,5 bar 2,54