1 | Pipe roller
Pipe roller, 1 steel-roller with ball bearings, steel construction galvanized, with base plate.

,Duct-pipe-laying-rollers,Duct-pipe-pulling-heads,Duct-pipe-mounting-tools,Duct-pipe-rounding-tongs,Duct-pipe-cutting-tongs,Conduit-duct-saw,Pipe-burring-tools,Paring-knife,Screw-socket-fittings,Conduit-unions,Halved-conduits,Duct-pipe-couplings,Conduit-duct-brush,Duct-pipe-pressure-test,Mini-transmitters,Duct-pressure-recorder,Duct-shuttoff-bladder,Duct-test-bladder,Protective-cable-bows,Lead-in-tubes,Galets-la-pose-conduit-tube,Têtes-tirage-conduit-tube,Tenailles-arrondir-conduit-tube,Ebarber-conduit-tube,Cisaille-coupe-conduit-tube,Clés-machons,Manchon-conduit-tube,Raccord-conduit-tube,Demi-conduit-tube,Coupe-conduit-tube,Brosse-tuyau-nylon,Mandrins-conduit-tube,Calibre-conduit-tube,Lubrifiant-câbles-et-conduit-tube,Système-calibrage-conduit-tube,Emetteur-conduit-tube,Enregistreur-pression-conduit-tube,Obturateur-conduit-tube,Membrane-test,Goutières-coude-protection-câbles,Rodillos-rulos-tender-conductos-tubos,Cabeza-tiro-conductos-tubos,Mallas-tira-conductos-tubos,Cortadores-conductos-tubos,Tenazas-redondear-conductos-tubos,Sierra-circular-conductos-tubos,Desbarbadora-conductos-tubos,Llave-manguitos-conductos-tubos,Tronzadoras-conductos-tubos,Escobillas-conductos-tubos-nylon,Calibres-conductos-tubos,Comprobación-impresión-estanqueidad-conductos-tubos,Emisor-conductos-tubos,Tapónes-obturador-conductos-tubos-y-cables,Registradores-presión-conductos-tubos,Cierre-conductos-tubos,Membranas-testar-conductos-tubos
CodeTypeRoller-D Mat. D-OD SWL L/W/H mm kg
201080 TRS 1-300120/76/185 Steel to 300 200 kg 320x235x145 5,20
2 | Pipe roller
Pipe roller, 1 polyamide-roller with friction bearings, steel construction galvanized

,,,
CodeTypeRoller-D Mat. D-OD SWL L/W/H mm kg
201100 TRP 1-500115/75x200 Poly. to 500 200 kg 270x200x145 5,30
3 | Pipe roller
Pipe roller, 1 steel-roller with ball bearings, steel construction galvanized.

,,,
CodeTypeRoller-D Mat. D-OD SWL L/W/H mm kg
201125 TKS 1-160120/76/145 Steel to 160 200 kg 250x230x240 4,20
4 | Pipe roller
Pipe roller, 1 base- 2 lateral alu-rollers and bearings for special aluminium, steel construction galvanized.

,,,
CodeTypeRoller-D Mat. D-OD SWL L/W/H mm kg
201172 TKR 3-16050 Alu to 160 150 kg 300x250x250 5,40
5 | Fixing nails
Fixing nails steel galvanized for fixing of all cable and pipe rollers to the ground.

,Fixing nails,,
,,,
CodeTypeSteel-D Length kg
205690 BN 3016 30 cm 0,50
205710 BN 5016 50 cm 1,05
6 | Pipe roller
Pipe roller, 2 high wattage-steel-rollers D 60 with ball bearings. Steel construction galvanized

,,,
,,,
CodeTypeRoller-D Mat. D-OD SWL L/W/H mm kg
201250 TVR 2-50060x200 Steel to 500 1000 kg 540x395x205 12,60
201270 TVR 2-76060x360 Steel to 760 1000 kg 880x395x256 20,40
7 | Pipe roller hydr. adjustable
Pipe roller hydr. height adjustable for pipe diam. up to 1500 mm, 2 high wattage-steel-rollers D 60 with ball bearings. Steel construction galvanized

,,,
CodeTypeRoller-D Mat. D-OD SWL L/W/H mm kg
201280 TVH 2-150060x630 Steel to 1500 1000 kg 960x395x300 33,40
8 | Leading-in funnel
Cable leading-in funnel, flexible metal hose for introducing all kind of cables into ducts in any position. Two mounted steel ropes lengthwise avoid damaging the flexible hose. During introducing of the cable the cables can be lubricated automatically and evenly on their whole length. Steel galvanized. These funnels can be supplied in different diameters and lengths.

,,,
,,,
,,,
CodeTypeFor D-ID Length Safety kg
273050 MET 75/3069-72 3,00 m 2 steel ropes 10,40
273100 MET 98/1898-100 1,80 m 2 steel ropes 8,80
273108 MET 98/4098-100 4,00 m 2 steel ropes 12,90
9 | Protective cable bows
Protective bow for pulling-in multiple ducts, steel sheet galv.

,,,
CodeTypeFor multiple ducts Width kg
209230 RSB 2002x35+2x28 200 7,00
10 | Pulling head
Pulling head for multiple conduits D 40 and 32 mm into ducts of D 110 mm.

,,,
CodeTypeFor D-D Max. Pull kg
273129 MZK 4/402x35+2x28 16 kN 1,40
11 | Duct pulling grip
Duct pulling grip for pulling multiple conduits into ducts of D 110 mm. Opening D 85-100, Length 1650 mm.

,,,
CodeTypeCap.-D kN L1/L2 kg
273270 MR 100/185-100 83,7 1500/1650 1,20
12 | Pipe pulling heads
Pipe pulling heads for pulling in of PE-HD-pipes PN 6 and PN 10. Steel galvanized, without sealing. With sealing see PDF-Drawing, available on request.

,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeD-ID Max. pull kg
273131 RZK 3225- 28 4 kN 0,40
273132 RZK 4031- 36 5 kN 0,54
273133 RZK 5039- 47 6 kN 1,20
273134 RZK 6349- 60 10 kN 1,55
273136 RZK 7559- 70 11 kN 2,20
273138 RZK 9071- 85 16 kN 3,85
273140 RZK 11087-103 25 kN 7,80
273142 RZK 12599-116 32 kN 12,60
273144 RZK 140111-130 40 kN 14,10
273146 RZK 160127-148 53 kN 19,40
27314610 RZK 180144-166 53 kN 22,00
13 | Mounting tool for ducts
Mounting device for conduit sleeves, steel construction galvanized.

,,,
,,,
,,,
,,,
CodeTypeD-OD kg
239400 MRM 3232 2,50
239410 MRM 4040 2,70
239420 MRM 5050 2,85
239430 MRM 110110 8,00
14 | Mounting tool for halved ducts
Mounting device for closing halved conduits, steel construction galvanized.

,,,
,,,
,,,
,,,
,,,
CodeTypeD-OD kg
239440 MGK 3232 0,41
239445 MGK 4040 0,44
239450 MGK 5050 0,47
239470 MGK 110110 2,80
239480 MGK 125125 2,80
15 | Rounding tongs
Rounding tongs for correcting deformed conduits.

,,,
,,,
,,,
CodeTypeD-OD kg
273240 RZA 3232 0,65
273245 RZA 4040 0,70
273250 RZA 5050 1,20
16 | Conduit cutters
Conduit cutters for plain cuts.

,,,
,,,
,,,
,,,
CodeTypeD-OD Length kg
273171 MRS 43to 42 215 0,45
273172 MRS 50to 50 265 0,60
273173 MRS 63to 63 285 0,70
273174 MRS 75to 75 485 1,60
17 | Burring tools
Burring tools for in- and outside of plastic conduits.

Paring knife MSM 40, for separating multiple conduits.
,,,
,,,
,,,
CodeTypeD-OD Burring Mat. kg
273185 MRA 6320-63 only extern Poly. 0,25
273180 MRE 5028-50 ext. /intern Alu 0,43
273200 MSM 40Paring knife --- Steel 0,50
18 | Conduit and cable slitter
Conduit slitter for lengthwise and circumferential slitting of plastic conduits and cable covers. Complete reinforced steel version. In case 195x75x45 mm.

,,,
,,,
CodeTypeTo wall thickness L/W/H mm kg
255905 KMS 66 195x75x45 0,35
255910 ERM 6Spare knife --- 0,03
19 | Spanner
Spanner (pair) for screw socket fittings.

,,,
,,,
,,,
CodeTypeD-OD Material kg
273420 MS 164016- 40 Plastic 0,14
273440 MS 407540- 75 Alu 0,60
273460 MS 6312563-125 Alu 1,75
20 | Screw socket fittings
Screw socket fittings for plastic conduits, air and water tight. Safest connection for blowing-in fibre optic cables.

,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeD-OD Press. kg
273520 SM 323232-32 PN 16 0,19
273530 SM 404040-40 PN 16 0,33
273540 SM 505050-50 PN 16 0,47
273550 SM 636363-63 PN 16 0,76
273616 RM 4032Reduction 40 to 32 PN 16 0,25
273620 RM 5032Reduction 50 to 32 PN 16 0,33
273630 RM 5040Reduction 50 to 40 PN 16 0,50
273670 RM 6350Reduction 63 to 50 PN 16 0,73
21 | Conduit union
Screwed conduit union, length 1,20 m, PN 10. If this union is mounted before blowing in the first cable, it can be opened and closed again anytime e.g. for blowing-in further cables in the same duct.

,,,
,,,
CodeTypeD-OD Press. Length kg
273720 RV 324032 PN 10 1,20 m 0,86
273730 RV 405040 PN 10 1,20 m 1,46
22 | Halved conduits
Halved conduits, for completion split sockets for halved conduits and mounting tools, see code 239.440-450 are necessary.

,,,
,,,
,,,
CodeTypeD-OD Length kg
273702 KHR 3232 2,00 m 0,72
273705 KHR 4040 2,00 m 0,92
273711 KHR 5050 2,00 m 1,24
23 | Split sockets
Split sockets for closing halved conduits.

,,,
,,,
,,,
CodeTypeD-OD kg
273713 KHM 3232 0,27
273714 KHM 4040 0,29
273715 KHM 5050 0,32
24 | Conduit cutting tool
Conduit cutting and bevelling tool, clamping jaws for smaller tubes to D 40 mm see below.

,,,
,,,
CodeTypeFor ducts to kg
239010 ROC 110OD 110 1,80
239240 SP 1116Spare knife reinforced for ROC 110-160 0,01
25 | Clamping jaws
Clamping jaws for ROC 110 and ROC 160 for smaller ducts

,,,
,,,
,,,
,,,
,,,
CodeTypeFor device For ducts to kg
239020 SPA 90ROC 110 D 90 0,30
239030 SPA 75ROC 110 D 75 0,30
239040 SPA 63ROC 110 D 63 0,30
239050 SPA 50ROC 110 D 50 0,30
239070 SPA 40ROC 110 D 40 0,30
26 | Cases for cutting tools
Case for conduit cutting and bevelling tool ROC 110 and ROC 160

,,,
CodeTypeFor device kg
239130 RK 110ROC 110 1,20
27 | Conduit brushes, nylon
Conduit brushes synthetic bristles the ext. diameter should be approx. 5-10 mm smaller than the int. diameter of the duct.

,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeOD Brush-L Total-L kg
230328 RNB 5757 195 315 0,90
230350 RNB 7777 250 410 1,00
230355 RNB 8585 250 410 1,20
230360 RNB 9292 250 410 1,20
230370 RNB 9797 250 410 1,20
230390 RNB 117117 250 410 1,60
230420 RNB 147147 250 410 2,10
230480 RNB 197197 250 410 2,50
28 | Conduit calibre balls
Conduit calibre balls, Polyamide, two pcs. special short length for passing narrow duct bows. The ball-Ø should be approx. 80-85 % of the nominal internal diam. of the duct.

,,,
,,,
CodeTypeD D-ID Calibre-L Connection kg
231250 KGP 37/3737 40-45 2x37 Clipper 0,32
231255 KGP 55/5555 60-70 2x55 Clipper 0,44
29 | Conduit calibre
Conduit calibre of polyamide. The calibre diameter should be approx. 80-95 % of the nominal internal diameter of the duct. Please ask your customer which calibre diameter he expects.

,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeOD D-ID Calibre-L Total-L kg
231270 KDP 50/3636 40-45 110 190 0,30
231280 KDP 63/4545 51-56 150 230 0,45
231290 KDP 75/5555 61-71 200 300 0,85
231310 KDP 90/6565 74-84 200 300 1,00
231350 KDP 110/8585 90-104 200 310 1,10
231360 KDP 110/9090 100-104 200 310 1,20
231380 KDP 125/9595 102-104 250 350 1,60
231400 KDP 125/105105 113-118 250 350 2,10
231410 KDP 140/115115 126-132 250 350 3,10
231420 KDP 150/125125 134-144 250 350 3,60
231425 KDP 160/130130 134-150 250 350 3,90
231430 KDP 160/135135 144-155 250 350 3,40
231450 KDP 180/150150 160-170 250 350 5,00
231460 KDP 200/165165 180-190 250 350 6,00
231470 KDP 225/185185 200-225 250 360 7,30
30 | Lubricant gel for cable and ducts
Lubricant gel like, for medium up to heaviest cables, up to 80 % friction reducing. Also suitable to reduce strongly the friction pulling-in ducts in ducts.

For lubrication unique and ultimate classification, Water pollution class - non-hazardous, acc. to VCI-Conception. Safety data sheets are available.
,,,
,,,
,,,
,,,
CodeTypePack. drums Units kg
235140 J-128V1 pail 3,8 l Single pail 4,00
235142 J-128V4 pails à 3,8 l Single pail 17,00
235150 J-640V1 pail 19 l Single pail 20,00
235152 J-640V33 pails 19 l 1 Pallet 685,00
31 | Lubricant pump
Lubricant pump driven by an external screw driver, for mounting on the pails J-640V or on the barrel SP-640V. Three different ration settings allow the user to pump lubricants with a variety of viscosities, from liquids to gels. Most lubricants can be pumped directly to the conduit or onto the cable during installation. Two hand-free applicators for conduits from diameter 40 to 150 mm are included.

,,,
CodeTypeCapability Hose kg
235335 LP-D55 l/min. 3 m 2,00
32 | Lubricant liquid for cables and ducts
Lubricant liquid, for medium up to heaviest cables, excellent distribution on the cable and in the duct, up to 80 % friction reducing. Also suitable to reduce strongly the friction pulling-in ducts in ducts.

For lubrication unique and ultimate classification, Water pollution class - non-hazardous, acc. to VCI-Conception. Safety data sheets are available.
,,,
,,,
,,,
,,,
,,,
CodeTypePack. drums Units kg
235200 SP-128V1 bottle 3,8 l single bottle 4,00
235202 SP-128V4 bottles 3,8 l single bottle 17,00
235220 SP-640V1 pail 19 l single pail 20,00
235222 SP-640V33 pails 19 l 1 Pallet 685,00
235230 SP-190V1 barrel 190 l Barrel 220,00
33 | Low air pressure tests
The new pressure test device combines three test methods in one electronic device. “General test rules” individual selectable acc. requirements from the customer. The requirement from Deutsche Telekom acc. “ZTV-TKNETZ 40”. The low-pressure test acc. EN 1610:2015 as well as worksheet DWA-A-139:2009

The low-pressure test is exclusively performed for leakage test of cable ducts with small wall-thickness. Those are being used for pulling of various cable types. The target is to proof the tightness against intrusion of groundwater, sand, sediments, etc. Those elements soils the protective ducts and complicate the pulling of cables.

With regards to the test methods those refers to the existing requirement of acceptance of waste water drain and ducts. For the testing of protective ducts the version “air” will be used only. Customers request low-pressure test of protective ducts against DIN EN 1610:2015 and acc. procedure “air” in the version LC or LD.
  • According which test method is determined by the customer “General test rules”.
  • Version LC, test pressure 0,1 bar (100 mbar, 10 kPa), duration 3 min, permitted pressure drop 15 mbar (1,5 kPa)
  • Version LD, test pressure 0,2 bar (200 mbar, 20 kPa), duration 1,5 min, permitted pressure drop 15 mbar (1,5 kPa)
,Low pressure test device,Duct-pipe-calibration-set,Duct-pipe-pressure-test,,
CodeTypeExplanation kg
231710 Low pressureSee the following devices 0,00
34 | High and low air pressure testing devices
The DPG 17U Universal pressure test device for test of cable ducts with regards to protective ducts and subducts working in the range of 0…7 bar. The operation is made by a 7” colour-graphic-touch display. The new device support the user through a simple and menu-driven operation. With the help of a matrix (table) three different test methods can be selected. Those are “General test rules” individual selectable acc. requirements from the customer, the requirement from Deutsche Telekom acc. “ZTV-TKNETZ 40” and the low-pressure test acc. “EN 1610:2015”. This results in a maximum support for the user.

The result of the pressure test is summarized in a clear test protocol with three core areas. The test protocol will be stored on the device and can be loaded by a USB-interface to a customary PC. ?
The left shown 1. protocol shows a passed test “Test criteria fulfilled” ?
The left shown 2. protocol shows a failed test “Test criteria not fulfilled”
  • Upper area: General data like: Contracting company with name of operator, construction site, duct, temperature, times, measurement data with calibration status
  • Middle area: Result of the pressure test through colour-marked message: “Test criteria fulfilled” or “Test criteria not fulfilled”
  • Lower area: Graph with the two phases settling time and main test
,,,
CodeTypeDesignation Press. Application kg
231740 DPG 17UUniversal pressure test device 0-7 bar Cable conduits 6,40
35 | Pressed air connectors
Low-pressure connection unit for pressure test of 1 cable duct for power- and fibre cable installation.

The low-pressure test is exclusively performed for leakage test of cable ducts with small wall-thickness. Those are being used for pulling of various cable types. Thereby the DN 110 is the most frequently used protective duct. The range of avail-able connection accessories is from duct-ID 70 until 200 mm.
,,,
CodeTypeDesignation Connection Press. kg
231757 NDA 02Air distribution 1 0-1,5 bar 21,00
36 | Shut-off bladder Mini
Shut-off bladders to lock off the pipeline to be tested. Shut-off bladders are used on the opposite side of the test location. The short dimensions of the Mini version allow space-saving installation of pipe bends also.

,,,
,,,
,,,
CodeTypeFor pipe-ID Cyl.-D Cyl.-L Total-L kg
231768 SBM 7/1070-100 68 130 175 0,40
231770 SBM 8/1580-150 72 120 170 0,40
231772 SBM 12/20125-200 115 150 195 0,80
37 | Test bladder Mini
Test bladders Mini for testing and shutting off pipes for low pressure testing.

Air coupling (brass) standard for bladder extension. Air coupling (chromed) special CE-standard 10.4 mm, for inflating the duct.
,,,
,,,
,,,
,,,
CodeTypeFor pipe-ID Cyl.-D Cyl.-L Total-L kg
231776 PBM 4/0740-70 38 155 215 0,40
231778 PBM 7/1070-100 68 190 340 1,10
231780 PBM 10/15100-150 90 150 300 1,33
231782 PBM 15/20150-200 145 195 345 2,83
38 | Foot pump with double stroke
Foot pump with double stroke and safety valve 2.5 bar to inflate SBM shut-off bladders and PBM test bladders. The use of a second foot pump for the second pipe end saves considerable installation time.

,,,
CodeTypePress. kg
231786 FP 2.52,5 bar 2,54
39 | Duct calibration set
Conduit calibration and leakage-test unit. Calibration and leakage-test before starting the cable blowing-in procedure is the safest guarantee for successful installation of fibre optic cables. Unit consisting of:
  • Compressed air regulator with adjustable tripod.
  • 5 m high pressure hose, calibre D 35, transmitter, for duct-D 50x4,6.
  • All other diam. of calibres are available, please see extensions below.
  • With conduit plug and catch box for the piston.
  • With electronic detector 33 kHz . Compl. set in alu-case 780x380x330.
  • Max. pressure setting 2-3 bar.
,High pressure test device,Duct-pipe-calibration-set,Duct-pipe-pressure-test,Système-calibrage-conduit-tube,Test-d'étanchéité-conduit-tube,Calibración-conductos-tubos,Comprobación-de-impresión,Estanqueidad-conductos-tubos
CodeTypeD-ID kg
231601 RKV 4040-41 27,00
40 | Calibre extension set
Supplementary extension set for calibration and leakage test unit.

,,,
,,,
CodeTypeD-ID kg
231602 RKVE 3333-34 2,60
231603 RKVE 2727-28 2,00
41 | Calibre housings
Calibre housings of polyamide with sleeve rings, without transmitter. Calibre length 145 mm, total length 250 mm

,,,
,,,
,,,
,,,
CodeTypeCalibre D/L/total Air max. D-ID kg
231644 MKV 4545/145/250 2-3 bar 51-52 0,45
231646 MKV 3535/145/250 2-3 bar 40-41 0,36
2316475 MKV 2828/145/250 2-3 bar 33-34 0,29
231648 MKV 2525/145/250 2-3 bar 27-28 0,32
42 | Miniature transmitter D 18 mm
Miniature transmitter D 18x88 mm, incl. battery, suitable for all a. m. calibres.

,,,
,,,
CodeTypeD/L Frequ. Thread Depth Cap. kg
231621 SKS 18N18/88 33 kHz M 10 8,0 m 20 h 0,23
097300307 Spare-battery 3,6V -- -- 20h 0,01
43 | Conduit plug for duct-OD
Conduit plug for fixing on duct-OD with hose safety coupling applicable for duct calibration, duct pressure tests, duct cleaning etc.

,,,
,,,
,,,
,,,
,,,
CodeTypeD-OD Press. kg
2316513 KRA 3232 mm 0-7 bar 0,50
231651 KRA 4040 to 6 bar 0,84
231650 KRA 5050 to 6 bar 0,90
231649 KRA 6363 to 6 bar 1,00
2316541 KRA 110110 mm 0-7 bar 3,20
44 | Sealing plug
Conduit sealing plug applicable for duct pressure tests.

,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeD-OD Press. kg
273569 ENSA 2020 to 6 bar 0,07
273572 ENSA 3232 to 6 bar 0,10
273575 ENSA 4040 to 6 bar 0,23
273580 ENSA 5050 to 6 bar 0,29
273585 ENSA 6363 to 6 bar 0,40
273586 ENSA 110110 to 6 bar 1,93