1 | Cable pulling heads
Cable pulling heads for single-conductor cables. Mounted directly on the conductor, for this much higher pulling forces are possible compared with cable grips acting on the cover. For high voltage cables 110-550 kV, from 800-3200 mm². Easy mounting procedure on cable manufacturers place or in the field within 2-3 minutes. This pulling heads are reusable continuously.
  • Before dispatch of the cable one needs: 1 cable sleeve, 1 taper key, 1 cap.
  • Before pulling the cable the cap will be unscrewed and the fork head screwed on the sleeve.
  • Before cable pulling a cardan link and a swivel must be mounted on the pulling head.
,Cable-pulling-heads,Cable-swivels,Cardan-joint,Têtes-tirage-câbles,Emerillons-lignes-aériennes,Cabezas-tiracables
CodeTypeNeeded parts
243600 KZK-KombiSee description above 0,00
2 | Cable jointing sleeves
Cable jointing sleeves for cable pulling-heads for pre-mounting on the conductor of high voltage cables.
  • For high voltage cables 110-550 kV with CU- or AL-conductor of 400-2500 mm²
  • Easy and fast mounting in the factory or on the working site in approx. 2-3 minutes.
  • These pulling heads can be re-used many times.
  • kN = Minimum Breaking Load
,,,
,,,
,,,
,,,
,,,
CodeTypeCross section Cond.-D OD kN kg
243911 KZH 06-630630 mm² 30-32 65 125 2,45
243922 KZH 08-1200800-1200 mm² 34-44 76 240 2,50
243941 KZH 12-16001200-1600 mm² 44-53 86 320 4,00
243956 KZH 20-25002000-2500 mm² 53-66 100 500 5,60
2439562 KZH 25-32002500-3200 mm² 66-74 115 500 6,00
3 | Fork head
Fork heads for screwing on cable jointing sleeves immediately before pulling the cable in.
  • On the site 1-2 fork heads will be enough.
  • kN = Minimum Breaking Load
,,,
,,,
,,,
,,,
,,,
CodeTypeCross section Sleeve Fork Bolt kN kg
243912 GAB 06-630630 mm² D 65 26 24 300 1,60
243923 GAB 08-1200800-1200 mm² D 76 30 27 320 2,17
243942 GAB 12-16001200-1600 mm² D 86 35 30 400 3,10
243957 GAB 20-25002000-2500 mm² D 100 38 36 500 5,50
2439572 GAB 25-32002500-3200 mm² D 115 38 36 500 7,00
4 | Hollow cone taper key
Hollow cone taper key for cable pulling heads for segmented conductors.
  • Segment conductors with a centre rope need hollow taper keys.
  • Exact conductor diameter is needed for an offer
  • Also diameter of the centre core is needed.
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeCross section Cond.-D kg
243926 KEIH 43-12001200-1400 mm² 42,0-43,3 0,17
243943 KEIH 46-14001200-1400 mm² 44,0-46,7 1,00
243945 KEIH 50-16001200-1600 mm² 48,0-50,3 0,70
243947 KEIH 53-16001400-1600 mm² 51,0-53,0 0,30
243950 KEIH 55-20001400-1600 mm² 53,2-56,5 0,35
243958 KEIH 57-25002000-2500 mm² 56,6-59,0 1,40
2439601 KEIH 60-20002000-2500 mm² 58,5-60,5 1,03
243961 KEIH 59-25002000-2500 mm² 59,0-63,0 1,00
243960 KEIH 63-25002000-2500 mm² 63,0-66,0 0,70
2439612 KEIH 66-32002500-3200 mm² 66,1-68,5 1,00
2439614 KEIH 68-32002500-3200 mm² 68,6-71,2 1,00
5 | Solid cone taper key
Solid cone taper key for cable pulling heads for round conductors.
  • For stranded conductors plane solid keys are used.
  • Exact conductor diameter is needed for an offer
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeCross section Cond.-D kg
243924 KEIV 35-800800-1200 mm² 32,0-34,8 0,40
2439241 KEIV 37-800800-1200 mm² 34,9-36,9 0,34
243925 KEIV 39-1000800-1200 mm² 37,0-39,3 0,28
2439251 KEIV 41-1000800-1200 mm² 39,5-42,2 0,21
2439254 KEIV 44-1000800-1200 mm² 41,6-43,5 0,15
2439255 KEIV 46-10001200-1600 mm² 43,6-45,5 0,20
2439256 KEIV 48-10001200-1600 mm² 45,6-47,5 0,20
2439583 KEIV 36-16002000-2500 mm² 52,7-54,4 1,40
243959 KEIV 56-23002000-2500 mm² 55,5-58,0 1,50
2439591 KEIV 67-32002500-3200 mm² 65,5-67,4 1,66
6 | Mounting tool
Mounting tool for all cable pulling heads for segment conductors with central rope. Made of special high quality steel, for beating in round taper keys.

,,,
,,,
,,,
CodeTypeCross section Central rope Dimension kg
243997 KMB 12-16001200-1600 mm² D 11 D 22x200 0,80
243998 KMB 20-25002000-2500 mm² D 17 D 28x200 0,90
243999 KMB 25-32002500-3200 mm² D 20 D 34x200 1,00
7 | Cardan joint
Cardan joint for flexible connection of the cable pulling heads with the pulling rope-swivels.
  • Together with the swivels it functions like a globe joint.
  • Important for pulling the cable through curves in different directions.
  • kN = Minimum Breaking Load
,,,
,,,
,,,
,,,
CodeTypeTo pull head Swivel kN kg
243976 KKG 06-630OD 65 V 55 D 180 2,60
243978 KKG 08-1200OD 76 V 65 D 280 4,10
243982 KKG 12-1600OD 86 V 75 D 500 6,45
243985 KKG 20-3200OD 100-115 V 75 D 500 6,70
8 | Swivels
Swivels with friction bearings, turnable connector between winch rope and cable grip. The friction bearing guarantees that the swivel reduces rotation and torsion with increasing pulling force. Only for underground cables, not suitable for pulling overhead lines.
 
kN = Minimum Breaking Load
  • Swivels for underground cables must be equipped only with friction bearings.
  • With increasing pulling force friction bearings twist harder and thus avoid the untwisting of the pulling rope
  • Ball bearings let untwist the ropes and leads to destruction.
  • kN = Minimum Breaking Load
,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeCross section D L Fork Bolt. kN kg
243140 V 50 D300 mm² 50 187 18 16 165 1,90
243150 V 55 D630 mm² 55 190 20 18 180 2,30
243180 V 65 D800-1200 mm² 65 235 26 24 300 3,42
243190 V 75 D1200-2500 mm² 75 270 30 27 320 6,70
243200 V 85 D1200-2500 mm² 85 315 34 30 400 9,40
243220 V 100 D1200-2500 mm² 100 350 38 36 500 14,50
9 | Closing cap
Closing cap with eye nut for screwing on the cable jointing sleeves.
  • With the caps screwed on the cones the cable ends can be fixed on the drum.
  • For pulling the cable, the cap will be unscrewed and replaced by the fork head.
  • In no case must be pulled cables using this cap.
,,,
,,,
,,,
,,,
,,,
CodeTypeFor sleeve-D kN kg
243965 ADK 65-63065 not for cable pulling 1,20
243968 ADK 76-120076 not for cable pulling 1,25
243970 ADK 86-160086 not for cable pulling 1,40
243972 ADK 100-2500100 not for cable pulling 1,60
2439722 ADK 115-3200115 not for cable pulling 2,00
10 | Cable guiding cones
Cable guiding cones of polyamide for soft running through the rollers of cable pulling heads.
  • The cones should be used if the cable is much bigger than the pulling head.
  • This combination guarantees a friction-free rolling of the cable through all parts of the roller line.
,,,
,,,
,,,
CodeTypePoly.-D For sleeve kg
24399126 KFK 76-13076/130/110 D 76 0,57
24399250 KFK 86-13086/130x130 D 86 0,44
24399445 KFK 100-140100/140x130 D 100 0,46