1 | Conduit cutters
Conduit cutters for plain cuts.

,Duct-pipe-calibration-set,Duct-pipe-pressure-test,Mini-transmitters,Cable-cutting-tongs,Pipe-test-bladder,Shuttoff-bladder,Conduit-duct-saw,Système-calibrage-conduit-tube,Test-d'étanchéité-conduit-tube,Cisaille-coupe-conduit-tube,Membrane-test,Cortadores-conductos-tubos,Membran-a-testar-conductos-tubos,Test-de-estanqueidad,Cierre-conductos-tubos,Scie-circular-conductos-tubos
,,,
,,,
,,,
CodeTypeD-OD Length kg
273171 MRS 43to 42 215 0,45
273172 MRS 50to 50 265 0,60
273173 MRS 63to 63 285 0,70
273174 MRS 75to 75 485 1,60
2 | Burring tools
Burring tools for in- and outside of plastic conduits.

Paring knife MSM 40, for separating multiple conduits.
,,,
,,,
,,,
CodeTypeD-OD Burring Mat. kg
273190 MRE 6328-63 only extern Poly. 0,20
273180 MRE 5028-50 ext. /intern Alu 0,43
273200 MSM 40Paring knife --- Steel 0,50
3 | Conduit and cable slitter
Conduit slitter for lengthwise and circumferential slitting of plastic conduits and cable covers. Complete reinforced steel version. In case 195x75x45 mm.

,,,
,,,
CodeTypeTo wall thickn. L/W/H mm kg
255905 KMS 66 195x75x45 0,35
255910 ERM 6Spare knife --- 0,03
4 | Cable conduit saw
This cable conduit saw SRS 6.1 is a further development of the proven SRS 6. The saw is suitable for cutting occupied and unoccupied cable conduits without damaging internal cables or subducts. The saw is suitable for conduits at an outer diameter of 32-150 mm and at a max. wall thickness up to 6 mm. The saw can precisely cut lengthwise and crosswise and can also precisely cut windows into the cable conduit. Especially for long cuts on the cable conduits which are necessary for cable line redirections the great benefits of this saw pay off.

The cutting depth can be precisely adjusted to a 1/10 of a millimetre by an adjustment mechanism thus the cables inside the cable conduit are well-protected. The cutting depth has always to be set 0,2 mm less than the conduits wall thickness. The remaining very thin plastic membrane will be removed by a lifter tool thus the cable is also protected during this final step.
 
The conduit guiding plates allow a high safety at work as well as accurate cuts. The guiding plates are available for the below mentioned conduit-diameters. The cordless saw is handy and small in order to be fit for application also in narrow working conditions its weight is below 2 kg. Included in delivery are the following parts:
  • Accu-saw with high-quality blade hard metal equipped and 3 accus with 1 charger
  • Precise pre-adjustment of the cutting depth, 1/10 mm accurate sliding calliper.
  • Lifter for the window-cutting rest
  • Packed and delivered in robust box, 445x355x255, weight app. 6,5 kg
  • Only approx. 1,9 kg of weight for comfortable application
,,,
,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeDevice For D-OD kg
273212 SRS 6.1Saw as above 32-150 6,50
273228 RFP 32Guide plate 32 0,35
273230 RFP 40Guide plate 40 0,32
273232 RFP 50Guide plate 50 0,26
273234 RFP 63Guide plate 63 0,26
273237 RFP 64+Guide plate 64-150 0,20
273222 ESB 6Spare blade --- 0,03
5 | Lubricant for FOC
Jettinglube lubricant for blowing-in fibre optic cables. Excellent lubricating effect. Adheres to the duct wall and leaves the cable nearly dry, an advantage for over blowing and working in cascades with further blowing machines. Consumption approx. 0,5 l per 1000 m at duct-ID 40 mm. For other duct-ID analogue

For lubrication unique and ultimate classification, Water pollution class - non-hazardous, acc. to VCI-Conception. Safety data sheets are available.
,,,
,,,
,,,
CodeTypePack. drums kg
234960 CJL 10321 bottle 0,95 l 1,00
234965 CJL 103212 bottles 0,95 l 12,00
234970 CJL 3784 bottles 3,80 l 16,00
6 | Lubricant liquid
Cable lubricant Softenol, liquid, for blowing-in and for pulling-in fibre optic cables.

For lubrication unique and ultimate classification, Water pollution class - non-hazardous, acc. to VCI-Conception. Safety data sheets are available.
,,,
,,,
,,,
,,,
CodeTypePack. drums kg
235800 SOF 051 canister 5 l 5,60
235810 SOF 101 canister 10 l 11,00
235830 SOF 251 canister 25 l 26,50
235890 SOF 1901 barrel 190 l 200,00
7 | Duct cleaning sponge
Sponge for duct cleaning and pre-lubricating prior to cable blowing

,,,
,,,
,,,
,,,
CodeTypeD-OD D-ID Cellular kg
275408 RSM 2832 28 D 45x90 0,01
275410 RSM 3540 35 D 55x90 0,01
275412 RSM 4050 40 D 65x90 0,01
275414 RSM 5163 51 D 78x90 0,02
8 | Duct calibration set
Conduit calibration and leakage-test unit. Calibration and leakage-test before starting the cable blowing-in procedure is the safest guarantee for successful installation of fibre optic cables. Unit consisting of:
  • Compressed air regulator with adjustable tripod.
  • 5 m high pressure hose, calibre D 35, transmitter, for duct-D 50x4,6.
  • All other diam. of calibres are available, please see extensions below.
  • With conduit plug and catch box for the piston.
  • With electronic detector 33 kHz . Compl. set in alu-case 780x380x330.
  • Max. pressure setting 2-3 bar.
,Duct-pipe-calibration-set,Duct-pipe-pressure-test,Système-calibrage-conduit-tube,Test-d'étanchéité-conduit-tube,Calibración-conductos-tubos,Comprobación-de-impresión,Estanqueidad-conductos-tubos
CodeTypeD-ID kg
231601 RKV 4040-41 27,00
9 | Calibre extension set
Supplementary extension set for calibration and leakage test unit.

,,,
,,,
CodeTypeD-ID kg
231602 RKVE 3333-34 2,60
231603 RKVE 2727-28 2,00
10 | Calibre housings
Calibre housings of polyamide with sleeve rings, without transmitter. Calibre length 145 mm, total length 250 mm

,,,
,,,
,,,
CodeTypeCalibre D/L/total Air max. D-ID kg
231646 MKV 3535/145/250 2-3 bar 40-41 0,36
2316475 MKV 2828/145/250 2-3 bar 33-34 0,29
231648 MKV 2525/145/250 2-3 bar 27-28 0,32
11 | Miniature transmitter D 18 mm
Miniature transmitter D 18x88 mm, incl. battery, suitable for all a. m. calibres.

,,,
,,,
CodeTypeD/L Frequ. Thread Depth Cap. kg
231621 SKS 18N18/88 33 kHz M 10 8,0 m 20 h 0,23
097300307 Spare-Battery 3,6V -- -- 20h 0,01
12 | Piston for loosing cables
Pistons for loosing old cables in ducts before blowing or pulling them out.

,,,
,,,
CodeTypeD-OD D-ID C-D kg
275230 LKO 4040 33-35 10-21 0,10
275232 LKO 5050 40-42 10-21 0,10
13 | Conduit plug for duct-OD
Conduit plug for fixing on duct-OD with hose safety coupling applicable for duct calibration, duct pressure tests, duct cleaning etc.

,,,
,,,
,,,
,,,
,,,
CodeTypeD-OD Press. kg
2316513 KRA 3232 to 6 bar 0,50
231651 KRA 4040 to 6 bar 0,84
231650 KRA 5050 to 6 bar 0,90
231649 KRA 6363 to 6 bar 1,00
2316541 KRA 110110 to 6 bar 3,20
14 | Sealing plug
Conduit sealing plug applicable for duct pressure tests.

,,,
,,,
,,,
,,,
,,,
,,,
CodeTypeD-OD Press. kg
273569 ENSA 2020 to 6 bar 0,07
273572 ENSA 3232 to 6 bar 0,10
273575 ENSA 4040 to 6 bar 0,23
273580 ENSA 5050 to 6 bar 0,29
273585 ENSA 6363 to 6 bar 0,40
273586 ENSA 110110 to 6 bar 1,93
15 | Pipe leakage test set
Pipe leakage test set 0-10 bar, for testing of 1-4 ducts simultaneously, independent of the diameter.

,,,
,,,
CodeTypeFor kg
2316291 RDP 10/11 duct 16,50
2316293 DPV 44 ducts 36,00
16 | Pressure recorder
Pressure recording device in completion to a. m. calibration and leakage unit. Electronic measuring of pressure and hardcopy on paper and storage for further computer handling of the data.

,,,
CodeTypeFor Max. test press. kg
231733 DRG 10any duct-D 10 bar 8,60
17 | Low pressure test set
The low pressure test sets are used exclusively for leakage testing cable conduits with small wall thicknesses which are used for pulling different types of cable. The low pressure test is intended to provide proof of tightness to prevent ingress of ground water, alluvial sand, sediments etc. These elements contaminate the cable conduit and complicate the pulling of cables. The low-pressure test set is based on the proven Vetter DRG 10 "high-pressure" leakage test unit and is offered in 3 versions which also relate to existing assemblies.
 
The test method resorts to existing regulations for the acceptance of sewers and drains. Only the "Air" version is used for the testing of cable conduits. Low pressure testing of cable conduits is currently still being requested by clients with the "Air" method, version LC, in accordance with DIN EN 1610. DIN EN 1610 is still valid, but somewhat outdated. Work sheet DWA-A 139-2009-12 is used to introduce changes for leakage testing according to the "Air" method. With respect to the above mentioned regulation, these changes affect designation and test duration.
  • The client decides which test method to use.
  • Method LC: test pressure 0.1 bar (100 mbar, 10 kPa), for 3 min., adm. pressure drop 15 mbar (1.5 kPa)
  • Method LE: test pressure 0.1 bar (100 mbar, 10 kPa), for 1.5 min., adm. pressure drop 15 mbar (1.5 kPa)
  • In special cases Deutsche Telekom may request a duct leakage test. The following test data are requested:
  • Test pressure 0,6-1,5 bar (subject to the depth), test duration 1 min.
  • Test pressure > 1 bar must be tested with 10 bar pressure sensor DRG 10
,,,
CodeTypeExplanation
231750 NDAsee above 0,00
18 | Low pressure add-on test set
This test system is an extension of the DRG 10 pressure recorder the user has available for testing cable conduits to blow up to 10 bar.

,,,
CodeTypeDesignation kg
231752 NDA 01Low pressure add-on test set 22,00
19 | Low pressure test set without battery printer
This complete test system works independently without printer. The measurement data is stored in the system and can be transferred to any PC and processed by means of an infrared interface cable forming part of the system.

,,,
CodeTypeDesignation kg
231754 NDO 01Low pressure test set without battery printer 26,00
20 | Low pressure test set with battery printer
This complete test system works independently with a battery printer. The measurement data is stored in the system and can be printed directly on the battery printer. The measurement data can also be transferred to a PC and processed by means of an infrared interface cable forming part of the system.

,,,
CodeTypeDesignation kg
231756 NDM 01Low pressure test set with battery printer 28,00
21 | Electric diaphragm pump
Electric diaphragm pump to inflate the pipelines to be tested during low pressure testing, including claw coupling 42. Max. pressure 200 mbar
  • Displacement at 100 mbar pressure: 160 l/min.
  • Displacement at 200 mbar pressure: 120 l/min.
,,,
CodeTypeEl-connection Sound L/W/H mm kg
231760 MPU 120230V/95W 45 db(A) 214/185/211 6,50
22 | Shut-off bladder Mini
Shut-off bladders to lock off the pipeline to be tested. Shut-off bladders are used on the opposite side of the test location. The short dimensions of the Mini version allow space-saving installation of pipe bends also.

,,,
,,,
,,,
CodeTypeFor pipe-ID Cyl.-D Cyl.-L Total-L kg
231768 SBM 7/1070-100 68 130 175 0,40
231770 SBM 8/1580-150 72 120 170 0,40
231772 SBM 12/20125-200 115 150 195 0,80
23 | Test bladder Mini
Test bladders Mini for testing and shutting off pipes for low pressure testing.

Air coupling (brass) standard for bladder extension. Air coupling (chromed) special CE-standard 10.4 mm, for inflating the duct.
,,,
,,,
,,,
CodeTypeFor pipe-ID Cyl.-D Cyl.-L Total-L kg
231778 PBM 7/1070-100 68 190 340 0,63
231780 PBM 10/15100-150 90 150 300 1,33
231782 PBM 15/20150-200 145 195 345 2,83
24 | Foot pump with double stroke
Foot pump with double stroke and safety valve 2.5 bar to inflate SBM shut-off bladders and PBM test bladders. The use of a second foot pump for the second pipe end saves considerable installation time.

,,,
CodeTypePress. kg
231786 FP 2.52,5 bar 2,40