1 | CableJet for FOC D 9-19 mm
CableJet for tension-free blowing-in of fibre optic cables D 9-19 mm. Worldwide thousand fold proven blowing machine. Basic machine without cable and duct inserts. See accessory below.
Average lengths are 2000 m and more.
Pneumatic cable drive, easy to control.
Electronic digital length- and speed measuring device
For ducts to D 50, compressors of a pressure of 12 bar at 10 m³/min. is necessary.
For ducts to D 63, compressors of a pressure of 12 bar at 14 m³/min. is necessary.
,CableJet,blowing-head,Fiber-optic,Cablejet,Superjet,Insufflage,insuffler,CableJet,insuflación,410100,CJS19
CodeTypeC-D For D-OD Air kg
410100 CJS 199-19 28-63 10 m³/12 bar 47,00
2 | Driving shafts for cable D 6-9 mm
Driving shafts for smaller cables D 6-9 mm, suitable to CableJet.

,,,,41015005,AWS6-9
CodeTypeC-D kg
41015005 AWS 6-96-9 1,40
3 | Accessory for FOC-floating
Accessory for FOC-floating with water for CableJet and SuperJet.
The CableJet and SuperJet are also able to float-in very long lengths of cables with water.
Cable lengths of 10 km were floated very successfully.
The procedure is very simple and big length will certainly be achieved.
Please ask for our special systems documents.
,,,,275210,REC15/1W
,,,,275213,RES15/1W
,,,,275216,GMT600
CodeTypeSuitable to C-D D-OD Press. kg
275210 REC 15/1WCablejet 9-19 28-63 4-8 bar 4,80
275213 RES 15/1WSuperJet 14-32 28-63 4-8 bar 3,45
275216 GMT 600SuperJet Lubricant funnel for all for all 1,00
4 | Y-duct connector
Y-duct connector for blowing-in a second or third cable in occupied ducts. Please select for this the corresponding cable and duct inserts. See table below of CableJet or SuperJet.
Allows to blow-in second or third cable in the same duct.
Also necessary for blowing of additional subducts in occupied ducts.
,Y-piece,Y-appareil,,410220,YK5050
,,,,41024510,KEY18
CodeTypeDuct inserts Cable inserts kg
410220 YK 50502 x for D-OD 50 incl. for 2 cables order separately 16,00
41024510 KEY 18 for 3rd cable order separately 0,46
5 | SuperJet for FOC D 12-34 mm
SuperJet for tension-free blowing-in of bigger fibre optic cables and bundles of sub ducts D 7-14 mm each. A very long belt drive of 330 mm secures a correct guide of cables and sub ducts. With digital length and speed meter. Including hydraulic power pack with petrol engine and control instruments. Worldwide thousand fold proven blowing machine. For successful blowing-in of big length, in ducts of D 50 mm a compressor of 12 bar and 10 m³/min. is necessary. Basic machine without belts, cable and duct inserts. See accessory below. Basic equipment consist of the following details:
Petrol-hydraulic pack with hoses
Length- and speed meter
Ball valve 1 1/2" with screw couplings.
Air pressure hose 1 1/2", length 10 m.
Compressor of min. 10 m³/12 bar for duct dia. 50x4,6
,,,,410314,SJH34
CodeTypeC-D Subducts Chain band Duct-D kg
410314 SJH 3414-32 D 7-14 L 330 28-63 125,00
6 | Creeper chain for cables
Creeper chain with rubber cams for blowing-in cables of D 14-32 mm with the SuperJet. Two are required.

,,,,042500209,PRO0820
,,,,0425002095,PRS0821
CodeTypeSuitable for C-D Required kg
042500209 PRO 0820SuperJet 14-32 2 1,60
0425002095 PRS 0821SuperJet Chain joint 2 0,02
7 | Driving chains for sub ducts
Driving chains of aluminium for blowing-in subducts with the SuperJet, combination see table below.

,Driving chains for sub ducts,Creeper chain for cables,Chaîne pour subducts,cadena para subducts,42107007,KET7/007
,,,,42107010,KET7/010
,,,,42111005,KET10/345
,,,,42111007,KET10/007
,,,,42111205,KET12/345
,,,,42111207,KET12/007
,,,,42111403,KET14/023
,,,,42111404,KET14/004
CodeTypeD-OD Subducts In D-OD kg
42107007 KET 7/0077 7 50 or 40 4,70
42107010 KET 7/0107 10 50 or 40 4,70
42111005 KET 10/34510 3/4/5 50 or 40 4,85
42111007 KET 10/00710 7 50 4,70
42111205 KET 12/34512 3/4/5 50 or 40 10,20
42111207 KET 12/00712 7 63 4,70
42111403 KET 14/02314 2/3 50 5,20
42111404 KET 14/00414 4 50 11,00
8 | Flat rubber chain
Flat rubber chain single incl. chain joint. This chain is mounted on the bottom to complete the existing chain of 5x7 / 5x10 and 5x12 for further subducts of 2x7 / 3x7 / 2x10 and 2x12 mm.

,,,,042113931,Flatchain
CodeTypeD-OD Subducts In D-OD kg
042113931 Flat chainsee text see text 50 or 40 1,00
9 | Cable inserts
Cable inserts suitable to CableJet and SuperJet. Also necessary for the Y-piece to blow-in a second or third cable in one duct. One set of cable sealing for the hole range of cable diameters is included.

,Cable-inserts,cablejet,superjet,,,41015009,KEJ9
,,,,41015011,KEJ11
,,,,41015012,KEJ12
,,,,41015014,KEJ14
,,,,41015015,KEJ15
,,,,41015018,KEJ18
,,,,41015022,KEJ22
,,,,41015024,KEJ24
,,,,41015028,KEJ28
,,,,41015032,KEJ32
CodeTypeC-D kg
41015009 KEJ 96,0- 9,0 0,46
41015011 KEJ 119,0-11,0 0,43
41015012 KEJ 1211,0-12,3 0,44
41015014 KEJ 1412,3-14,0 0,44
41015015 KEJ 1514,0-15,5 0,44
41015018 KEJ 1815,5-18,0 0,45
41015022 KEJ 2217,5-22,0 0,41
41015024 KEJ 2422,0-23,5 0,45
41015028 KEJ 2823,5-28,0 0,41
41015032 KEJ 3228,0-32,0 0,41
10 | Cable sealing
Cable sealing for CableJet and SuperJet. These are also useable in the Y-piece for blowing-in of further cables in the same duct.

,Cable-sealing,gasket,packing,washer,joint,bague,minijet,ultimaz,Anillo junta,Superjet,CableJet,minijet,Ultimaz,,415107,KDR07
,,,,415108,KDR08
,,,,415109,KDR09
,,,,415110,KDR10
,,,,415111,KDR11
,,,,415120,KDR12
,,,,415140,KDR14
,,,,415150,KDR15
,,,,415180,KDR18/16
,,,,41518017,KDR18/17
,,,,41518018,KDR18/18
,,,,415200,KDR20/18
,,,,41520020,KDR20/20
,,,,41522022,KDR22/22
,,,,415230,KDR24
,,,,415280,KDR25
,,,,41528026,KDR28/26
,,,,41528028,KDR28
,,,,41535030,KDR32/30
,,,,41535033,KDR32/32
CodeTypeC-D To insert Set of kg
415107 KDR 076,0-6,7 KEJ 9 20 half seals 0,01
415108 KDR 086,7-8,5 KEJ 9 10 cpl. seals 0,01
415109 KDR 098,5-9,0 KEJ 9 20 half seals 0,01
415110 KDR 109,0-10,3 KEJ 11 20 half seals 0,01
415111 KDR 1110,3-11,0 KEJ 11 20 half seals 0,01
415120 KDR 1211,0-12,3 KEJ 12 20 half seals 0,01
415140 KDR 1412,3-14,0 KEJ 14 20 half seals 0,01
415150 KDR 1514,0-15,5 KEJ 15 20 half seals 0,02
415180 KDR 18/1615,5-16,8 KEJ 18 20 half seals 0,02
41518017 KDR 18/1716,8-17,5 KEJ 18 20 half seals 0,02
41518018 KDR 18/1817,5-18,0 KEJ 18 20 half seals 0,02
415200 KDR 20/1817,5-18,3 KEJ 22 20 half seals 0,04
41520020 KDR 20/2018,3-20,4 KEJ 22 20 half seals 0,04
41522022 KDR 22/2220,4-22,0 KEJ 22 20 half seals 0,04
415230 KDR 2422,0-23,5 KEJ 24 20 half seals 0,03
415280 KDR 2523,5-25,0 KEJ 28 20 half seals 0,05
41528026 KDR 28/2625,0-26,4 KEJ 28 20 half seals 0,12
41528028 KDR 2826,4-28,0 KEJ 28 20 half seals 0,05
41535030 KDR 32/3028,0-30,0 KEJ 32 20 half seals 0,12
41535033 KDR 32/3230,0-32,0 KEJ 32 20 half seals 0,12
11 | Subduct chain inserts
Subduct chain inserts suitable to SuperJet to blow-in a bundle of subducts. Sealing set is included. Suitable to chains see table below.

,,,,41015035,SDJ36
,,,,41015042,SDJ42
CodeTypeFor subduct chains KET kg
41015035 SDJ 367/007 (7/010) (10/345) (10/007) 0,36
41015042 SDJ 4212/345 (12/0079) (14/023) (14/004) 0,36
12 | Subduct sealing
Subduct-sealing to subduct-inserts for SuperJet.

,,,,41535038,SDR36
,,,,41542044,SDR42
CodeTypeFor insert Set of kg
41535038 SDR 36SDJ 36 4 half seals 0,01
41542044 SDR 42SDJ 37 2 cpl. seals 0,06
13 | Duct inserts
Duct inserts suitable to CableJet, SuperJet. Also necessary for the Y-piece to blow-in a second or third cable in one duct.

,,,,41018032,REJ32
,,,,41018040,REJ40
,,,,41018050,REJ50
,,,,41018063,REJ63
CodeTypeD-OD kg
41018032 REJ 3232 1,40
41018040 REJ 4040 1,40
41018050 REJ 5050 1,40
41018063 REJ 6363 1,40
14 | Cable guiding heads
Cable guiding heads for screwing on the cables for low-friction sliding during cable-blowing. One set of 6 different cable diameters from 8,5 to 20 mm.

,Cable guides,heads,tips,Tête de guidage,insuflar,insuflación,microcables,minicables,410270,KFM82
CodeTypeFor C-D Head OD Set of kg
410270 KFM 828,5-20 15-22 6 0,11
15 | Sonic heads
Sonic heads for successful blowing-in of thin and soft fibre optic cables with the CableJet or the SuperJet for achieving of bigger lengths.
The sonic head opens and allows to pass 90 % of the cable supporting Jet-stream.
The pulling force exerting on the cable head is therefore only of some kg.
This pull as pre-tension is enough to carry soft cable straight on through the duct.
,,,,410600,SKO40
,,,,410620,SKO50
,,,,410640,SKO63
CodeTypeD-OD D-ID kg
410600 SKO 4032+41 26-32 0,48
410620 SKO 5040+50 32-41 0,59
410640 SKO 6363 40-51 0,88
16 | Duct cleaning sponge
Sponge for duct cleaning and pre-lubricating prior to cable blowing

,Duct-cleaning-sponge,Eponge nettoyage,Esponja limpieza,275408,RSM32
,,,,275410,RSM40
,,,,275412,RSM50
,,,,275414,RSM63
CodeTypeD-OD D-ID Cellular kg
275408 RSM 3232 28 D 45x90 0,01
275410 RSM 4040 35 D 55x90 0,01
275412 RSM 5050 40 D 65x90 0,01
275414 RSM 6363 51 D 78x90 0,02
17 | Cable crash test tube
Cable crash test tube transparent with sealing end. For limiting the pushing force of the blowing-in machines. Tests without compressed air. For determination of the cable stiffness up to the crash. Safe packed in reusable plastic duct.

,Cable crash test-tube,,,275312,CTR32
,,,,275315,CTR40
,,,,275318,CTR50
,,,,275321,CTR63
CodeTypeD-OD D-ID For C-D Length kg
275312 CTR 3232 28 to 15,0 1,65 m 0,80
275315 CTR 4040 34 to 16,0 1,65 m 1,10
275318 CTR 5050 42 to 20,0 1,65 m 1,30
275321 CTR 6363 54 to 25,0 1,65 m 1,70
18 | Duct coupler
Metallic duct coupler of aluminium, hinged, for coupling two cable ducts for blowing through cables. Up to air pressures 12 bars.

,Burring tools,Paring knife,Tenaille pour arrondir conduit,Ebarber,Cortador tubos,Tenazas para redondear tubos,275200,RK4040
,,,,275203,RK5050
,,,,275206,SW11
CodeTypeD-OD Max. press. kg
275200 RK 404040 12 bar 1,35
275203 RK 505050 12 bar 1,10
275206 SW 11Socked spinner wrench 0,18
19 | Cable duct connecting nipple
Cable duct connecting nipple for ducts, which are cut plain with the manhole wall. This connecting nipple with right- and left-hand thread enables a through-connection to blow-through cables. Afterwards the nipple can be opened lengthwise and be separated. Included are: 1 sickle spanner, 1 allan key and 2 pipe clamps.

,,,,410260,VB5050
,,,,410255,VB4040
CodeTypeNipple D-OD Length kg
410260 VB 5050ID 33 50 220 1,60
410255 VB 4040ID 25 40 220 0,90
20 | Conduit cutters
Conduit cutters for plain cuts.

,cutting-tongs,cutter,conduit saw,circular,Cisaille coupe conduites,Cortador tubos,273171,MRS43
,,,,273172,MRS50
,,,,273173,MRS63
,,,,273174,MRS75
CodeTypeD-OD Length kg
273171 MRS 43to 42 215 0,45
273172 MRS 50to 50 265 0,60
273173 MRS 63to 63 285 0,70
273174 MRS 75to 75 485 1,60
21 | Burring tools
Burring tools for in- and outside of plastic conduits.

Paring knife MSM 40, for separating multiple conduits.
,,,,273190,MRE63
,,,,273180,MRE50
,,,,273200,MSM40
CodeTypeD-OD Burring Mat. kg
273190 MRE 6328-63 only extern Poly. 0,20
273180 MRE 5028-50 ext. /intern Alu 0,43
273200 MSM 40Paring knife --- Steel 0,50
22 | Conduit and cable slitter
Conduit slitter for lengthwise and circumferential slitting of plastic conduits and cable covers. Complete reinforced steel version. In case 195x75x45 mm.

,,,,255905,KMS6
,,,,255910,ERM6
CodeTypeTo wall thickn. L/W/H mm kg
255905 KMS 66 195x75x45 0,35
255910 ERM 6Spare knife --- 0,03
23 | New Product - Cable conduit saw
This cable conduit saw SRS 6.1 is a further development of the proven SRS 6. The saw is suitable for cutting occupied and unoccupied cable conduits without damaging internal cables or subducts. The saw is suitable for conduits at an outer diameter of 32-150 mm and at a max. wall thickness up to 6 mm. The saw can precisely cut lengthwise and crosswise and can also precisely cut windows into the cable conduit. Especially for long cuts on the cable conduits which are necessary for cable line redirections the great benefits of this saw pay off.

The cutting depth can be precisely adjusted to a 1/10 of a millimetre by an adjustment mechanism thus the cables inside the cable conduit are well-protected. The cutting depth has always to be set 0,2 mm less than the conduits wall thickness. The remaining very thin plastic membrane will be removed by a lifter tool thus the cable is also protected during this final step.
 
The conduit guiding plates allow a high safety at work as well as accurate cuts. The guiding plates are available for the below mentioned conduit-diameters. The cordless saw is handy and small in order to be fit for application also in narrow working conditions its weight is below 2 kg. Included in delivery are the following parts:
Accu-saw with high-quality blade hard metal equipped and 3 accus with 1 charger
Precise pre-adjustment of the cutting depth, 1/10 mm accurate sliding calliper.
Lifter for the window-cutting rest
Packed and delivered in robust box, 445x355x255, weight app. 6,5 kg
Only approx. 1,9 kg of weight for comfortable application
,,,,273212,SRS6.1
,,,,273228,RFP32
,,,,273230,RFP40
,,,,273232,RFP50
,,,,273234,RFP63
,,,,273237,RFP64+
,,,,273222,ESB6
CodeTypeDevice For D-OD kg
273212 SRS 6.1Saw as above 32-150 6,50
273228 RFP 32Guide plate 32 0,35
273230 RFP 40Guide plate 40 0,32
273232 RFP 50Guide plate 50 0,26
273234 RFP 63Guide plate 63 0,26
273237 RFP 64+Guide plate 64-150 0,20
273222 ESB 6Spare blade --- 0,03
24 | FigarO the cable basket
FigarO. The FOC basket is used is the cable is to long to be blown completely with only one blowing machine. If half of the cable is installed in one direction the remaining cable is pushed into the FigarO with the blowing machine. Out of the FigarO this part of the cable can be blown uncut in the opposite direction to finish the installation.
To handle the FigarO see suitable trailer below.
Cable Cap.: 3000 m D 8 / 2700 m D 12 / 2300 m D 14.
The FigarO replaces laying figure of 8 on the ground, is clean and space saving.
The FigarO is always placed besides the cable drum.
,FigarO-basket,Figarino,figure-eight,Panier de câble,Figaro,Cesto,411210,SLK225
CodeTypeBasket-D kg
411210 SLK 2252250 159,00
25 | Trailer for FigarO
Trailer for the FigarO. After folding down both FigarO halves the cable can be pushed directly into the FigarO on an agreeable and safe height. Under the same condition the cable can afterwards also be blown into the duct. Trailer with alu platform, all side walls can be folded down. Height adjustable drawbar with ball coupling and parking brake.
On this trailer the FigarO can be replaced from pit to pit.
The cables stays away from mud on a good working height.
,Trailer-for-FigarO,,,275800,FAN440
CodeTypePlatform size Total Hitch kg
275800 FAN 4402300x1520x400 750 kg 75 kg 320,00
26 | Lubricant for FOC
Jettinglube lubricant for blowing-in fibre optic cables. Excellent lubricating effect. Adheres to the duct wall and leaves the cable nearly dry, an advantage for over blowing and working in cascades with further blowing machines. Consumption approx. 0,5 l per 1000 m at duct-ID 40 mm. For other duct-ID analogue

For lubrication unique and ultimate classification, Water pollution class - non-hazardous, acc. to VCI-Conception. Safety data sheets are available.
,Cable-duct-lubricant,grease,greasing,pump,Lubrifiant,Jettinglube,Microlube,lubrificante,jettinglube,microlube,234960,CJL1032
,,,,234965,CJL1032
,,,,234970,CJL378
CodeTypePack. drums kg
234960 CJL 10321 bottle 0,95 l 1,00
234965 CJL 103212 bottles 0,95 l 12,00
234970 CJL 3784 bottles 3,80 l 16,00
27 | Lubricant liquid
Cable lubricant Softenol, liquid, for blowing-in and for pulling-in fibre optic cables.

For lubrication unique and ultimate classification, Water pollution class - non-hazardous, acc. to VCI-Conception. Safety data sheets are available.
,,,,235800,SOF05
,,,,235810,SOF10
,,,,235830,SOF25
,,,,235890,SOF190
CodeTypePack. drums kg
235800 SOF 051 canister 5 l 5,60
235810 SOF 101 canister 10 l 11,00
235830 SOF 251 canister 25 l 26,50
235890 SOF 1901 barrel 190 l 200,00
28 | Duct calibration set
Conduit calibration and leakage-test unit. Calibration and leakage-test before starting the cable blowing-in procedure is the safest guarantee for successful installation of fibre optic cables. Unit consisting of:
Compressed air regulator with adjustable tripod.
5 m high pressure hose, calibre D 35, transmitter, for duct-D 50x4,6.
All other diam. of calibres are available, please see extensions below.
With conduit plug and catch box for the piston.
With electronic detector 33 kHz . Compl. set in alu-case 780x380x330.
,Pistons,pulling-heads, sonic-heads,ball-piston,mole,Système de calibrage,Calibrar,calibración,comprobación de impresión,estanqueidad,231601,RKV40
CodeTypeD-ID kg
231601 RKV 4040-41 27,00
29 | Calibre extension set
Supplementary extension set for calibration and leakage test unit.

,,,,231602,RKVE33
,,,,231603,RKVE27
CodeTypeD-ID kg
231602 RKVE 3333-34 2,60
231603 RKVE 2727-28 2,00
30 | Calibre housings
Calibre housings of polyamide with sleeve rings, without transmitter. Calibre length 145 mm, total length 250 mm

,Calibres,pressure-low-test,Système de calibrage,,231646,MKV35
,,,,2316475,MKV28
,,,,231648,MKV25
CodeTypeCalibre D/L/total D-ID kg
231646 MKV 3535/145/250 40-41 0,36
2316475 MKV 2828/145/250 33-34 0,29
231648 MKV 2525/145/250 27-28 0,32
31 | Miniature transmitter D 18 mm
Miniature transmitter D 18, suitable for all a. m. calibres.

,Detectors,mini-transmitters,Emitteur,Emisor,231620,SKS18
CodeTypeCalibre-D/L Frequency Thread Depth kg
231620 SKS 1818/100 33 kHz M 10 to 4,0 m 0,07
32 | Piston for loosing cables
Pistons for loosing old cables in ducts before blowing or pulling them out.

,Low-pressure,cable-loosing,Low-pressure,cable-loosing,Low-pressure,cable-loosing,275230,LKO40
,,,,275232,LKO50
CodeTypeD-OD D-ID C-D kg
275230 LKO 4040 33-35 10-21 0,10
275232 LKO 5050 40-42 10-21 0,10
33 | Conduit plug for duct-OD
Conduit plug for fixing on duct-OD with hose safety coupling applicable for duct calibration, duct pressure tests, duct cleaning etc.

,Conduit-duct-pipe,plug,Bouchon de fermeture,Tapón obturar tubos,2316513,KRA32
,,,,231651,KRA40
,,,,231650,KRA50
,,,,231649,KRA63
,,,,2316541,KRA110
CodeTypeD-OD Press. kg
2316513 KRA 3232 to 6 bar 0,50
231651 KRA 4040 to 6 bar 0,84
231650 KRA 5050 to 6 bar 0,90
231649 KRA 6363 to 6 bar 1,00
2316541 KRA 110110 to 6 bar 3,20
34 | Sealing plug
Conduit sealing plug applicable for duct pressure tests.

,,,,273569,ENSA20
,,,,273572,ENSA32
,,,,273575,ENSA40
,,,,273580,ENSA50
,,,,273585,ENSA63
,,,,273586,ENSA110
CodeTypeD-OD Press. kg
273569 ENSA 2020 to 6 bar 0,07
273572 ENSA 3232 to 6 bar 0,10
273575 ENSA 4040 to 6 bar 0,23
273580 ENSA 5050 to 6 bar 0,29
273585 ENSA 6363 to 6 bar 0,40
273586 ENSA 110110 to 6 bar 1,93
35 | Pipe leakage test set
Pipe leakage test set 0-10 bar, for testing of 1-4 ducts simultaneously, independent of the diameter.

,Pipe-leakage-set,Pipe-leakage-set,Pipe-leakage-set,2316291,RDP10/1
,,,,2316293,RDP10/4
CodeTypeFor kg
2316291 RDP 10/11 duct 16,50
2316293 RDP 10/44 ducts 36,00
36 | Pressure recorder
Pressure recording device in completion to a. m. calibration and leakage unit. Electronic measuring of pressure and hardcopy on paper and storage for further computer handling of the data.

,Pressure-low-recorder,Pressure-low-recorder,Pressure-low-recorder,231733,DRG10
CodeTypeFor Max. test press. kg
231733 DRG 10any duct-D 10 bar 8,60
37 | Low pressure test set
The low pressure test sets are used exclusively for leakage testing cable conduits with small wall thicknesses which are used for pulling different types of cable. The low pressure test is intended to provide proof of tightness to prevent ingress of ground water, alluvial sand, sediments etc. These elements contaminate the cable conduit and complicate the pulling of cables. The low-pressure test set is based on the proven Vetter DRG 10 "high-pressure" leakage test unit and is offered in 3 versions which also relate to existing assemblies.
 
The test method resorts to existing regulations for the acceptance of sewers and drains. Only the "Air" version is used for the testing of cable conduits. Low pressure testing of cable conduits is currently still being requested by clients with the "Air" method, version LC, in accordance with DIN EN 1610. DIN EN 1610 is still valid, but somewhat outdated. Work sheet DWA-A 139-2009-12 is used to introduce changes for leakage testing according to the "Air" method. With respect to the above mentioned regulation, these changes affect designation and test duration.
The client decides which test method to use.
Method LC: test pressure 0.1 bar (100 mbar, 10 kPa), duration 3 min., adm. pressure drop 15 mbar (1.5 kPa)
Method LE: test pressure 0.1 bar (100 mbar, 10 kPa), duration 1.5 min., adm. pressure drop 15 mbar (1.5 kPa)
,,,,231750,NDA
CodeTypeExplanation kg
231750 NDAsee above 0,00
38 | Low pressure add-on test set
This test system is an extension of the DRG 10 pressure recorder the user has available for testing cable conduits to blow up to 10 bar.

,,,,231752,NDA01
CodeTypeDesignation kg
231752 NDA 01Low pressure add-on test set 22,00
39 | Low pressure test set without battery printer
This complete test system works independently without printer. The measurement data is stored in the system and can be transferred to any PC and processed by means of an infrared interface cable forming part of the system.

,,,,231754,NDO01
CodeTypeDesignation kg
231754 NDO 01Low pressure test set without battery printer 26,00
40 | Low pressure test set with battery printer
This complete test system works independently with a battery printer. The measurement data is stored in the system and can be printed directly on the battery printer. The measurement data can also be transferred to a PC and processed by means of an infrared interface cable forming part of the system.

,,,,231756,NDM01
CodeTypeDesignation kg
231756 NDM 01Low pressure test set with battery printer 28,00
41 | Electric diaphragm pump
Electric diaphragm pump to inflate the pipelines to be tested during low pressure testing, including claw coupling 42. Max. pressure 200 mbar
Displacement at 100 mbar pressure: 160 l/min.
Displacement at 200 mbar pressure: 120 l/min.
,,,,231760,MPU120
CodeTypeEl-connection Sound L/W/H mm kg
231760 MPU 120230V/95W 45 db(A) 214/185/211 6,50
42 | Shut-off bladder Mini
Shut-off bladders to lock off the pipeline to be tested. Shut-off bladders are used on the opposite side of the test location. The short dimensions of the Mini version allow space-saving installation of pipe bends also.

,Shutt-off-bladder,Shutt-off-bladder,Shutt-off-bladder,231768,SBM7/10
,,,,231770,SBM8/15
,,,,231772,SBM12/20
CodeTypeFor pipe-ID Cyl.-D Cyl.-L Total-L kg
231768 SBM 7/1070-100 68 130 175 0,40
231770 SBM 8/1580-150 72 120 170 0,40
231772 SBM 12/20125-200 115 150 195 0,80
43 | Test bladder Mini
Test bladders Mini for testing and shutting off pipes for low pressure testing.

Air coupling (brass) standard for bladder extension. Air coupling (chromed) special CE-standard 10.4 mm, for inflating the duct.
,Test-bladder,,,231778,PBM7/10
,,,,231780,PBM10/15
,,,,231782,PBM15/20
CodeTypeFor pipe-ID Cyl.-D Cyl.-L Total-L kg
231778 PBM 7/1070-100 68 190 340 0,73
231780 PBM 10/15100-150 90 150 300 1,33
231782 PBM 15/20150-200 145 195 345 2,83
44 | Foot pump with double stroke
Foot pump with double stroke and safety valve 2.5 bar to inflate SBM shut-off bladders and PBM test bladders. The use of a second foot pump for the second pipe end saves considerable installation time.

,,,,231786,FP2.5
CodeTypePress. kg
231786 FP 2.52,5 bar 2,40
45 | Compressor diesel engine
High powered compressors for blowing-in bigger fibre optic cables. Suitable for CableJet and SuperJet and for duct ID up to 41 mm. Mounted on single axle trailer with height adjustable overrun drawbar. Incl. Diesel-Oxidation filter and particle filter. Emission standard IV and US-standard EPA Tier 4.
Deutz Diesel-engine, 105 kW. Compressor dimension: 5180x2130x1790
Flow rate 9,7 m³ at 14 bar, 10,70 m³, at 12 bar, 11,5 m³ at 7,0 bar working pressure
With integrated after cooler and water separator.
Incl. Diesel-Oxidation filter and particle filter
Diesel-Oxidation filter and particle filter. Emmission standard IV and US-standard EPA Tier 4.
,Compressors,Compresseur,compresores,960125,M125
CodeTypeAir Press. D-ID C-D kg
960125 M 1259,7-11,5 m³/min. 14-7 bar, s. above to 41 to 30 2.088,00
46 | Pressure release valve
Pressure release valve with sound absorber for compressors. Max. pressure 15 bar.

,,,,096010038,EVK34
,,,,275220,EVK15
CodeTypePress. For compressor kg
096010038 EVK 3415 bar MK 17 / M 31 1,30
275220 EVK 1515 bar M 125 2,70