1 | Duct calibration set
Conduit calibration and leakage-test unit. Calibration and leakage-test before starting the cable blowing-in procedure is the safest guarantee for successful installation of fibre optic cables. Unit consisting of:
Compressed air regulator with adjustable tripod.
5 m high pressure hose, calibre D 35 mm, transmitter, for duct-D 50x4,6 mm.
All other diam. of calibres are available, please see extensions below.
With conduit plug and catch box for the piston.
With electronic detector 33 kHz . Compl. set in alu-case 780x380x330 mm.
Duct-calibration-set,231601
CodeTypeDuct-ID kg
231601 RKV 4040-41 mm 27,00
2 | Calibre extension set
Supplementary extension set for calibration and leakage test unit.

Calibres,231602
Calibres,231603
CodeTypeDuct-ID kg
231602 RKVE 3333-34 mm 2,60
231603 RKVE 2727-28 mm 2,00
3 | Calibre housings
Calibre housings of polyamide with sleeve rings, without transmitter. Calibre length 145 mm, total length 250 mm

Calibres,231646
Calibres,2316475
Calibres,231648
CodeTypeCalibre-D Duct-ID kg
231646 MKV 3535 mm 40-41 mm 0,36
2316475 MKV 2828 mm 33-34 mm 0,29
231648 MKV 2525 mm 27-28 mm 0,32
4 | Miniature transmitter D 18 mm
Miniature transmitter D 18, suitable for all a. m. calibres.

Miniature transmitter D 18 mm,231620
CodeTypeCalibre-D/L Thread For depths kg
231620 SKS 1818/100 mm M 10 up to 4,0 m 0,07
5 | Conduit plug for duct-OD
Conduit plug for fixing on duct-OD with hose safety coupling applicable for duct calibration, duct pressure tests, duct cleaning etc.

Duct couplings,duct plugs,2316513
Duct couplings,duct plugs,231651
Duct couplings,duct plugs,231650
Duct couplings,duct plugs,231649
Duct couplings,duct plugs,2316541
CodeTypeDuct OD Pressure kg
2316513 KRA 3232 mm up to 10 bar 0,50
231651 KRA 4040 mm up to 10 bar 0,84
231650 KRA 5050 mm up to 10 bar 0,90
231649 KRA 6363 mm up to 10 bar 1,00
2316541 KRA 110110 mm up to 10 bar 3,20
6 | Sealing plug
Conduit sealing plug applicable for duct pressure tests.

Duct couplings,duct plugs,273569
Duct couplings,duct plugs,273572
Duct couplings,duct plugs,273575
Duct couplings,duct plugs,273580
Duct couplings,duct plugs,273585
Duct couplings,duct plugs,273586
CodeTypeDuct OD Pressure kg
273569 ENSA 2020 mm up to 10 bar 0,07
273572 ENSA 3232 mm up to 10 bar 0,10
273575 ENSA 4040 mm up to 10 bar 0,23
273580 ENSA 5050 mm up to 10 bar 0,29
273585 ENSA 6363 mm up to 10 bar 0,40
273586 ENSA 110110 mm up to 10 bar 1,93
7 | Pipe leakage test set
Pipe leakage test set 0-10 bar, for testing of 1-4 ducts simultaneously, independent of the diameter.

Pipe-leakage-test-set,2316291
Pipe-leakage-test-set,2316293
CodeTypeFor kg
2316291 RDP 10/11 duct 16,50
2316293 RDP 10/44 ducts 47,60
8 | Pressure recorder
Pressure recording device in completion to a. m. calibration and leakage unit. Electronic measuring of pressure and hardcopy on paper and storage for further computer handling of the data.

Pressure recorder,231733
CodeTypeFor Max. test pressure kg
231733 DRG 10all duct-D 10 bar 8,60
9 | Low pressure test set
The low pressure test sets are used exclusively for leakage testing cable conduits with small wall thicknesses which are used for pulling different types of cable. The low pressure test is intended to provide proof of tightness to prevent ingress of ground water, alluvial sand, sediments etc. These elements contaminate the cable conduit and complicate the pulling of cables. The low-pressure test set is based on the proven Vetter DRG 10 “high-pressure” leakage test unit and is offered in 3 versions which also relate to existing assemblies.
 
The test method resorts to existing regulations for the acceptance of sewers and drains. Only the “Air” version is used for the testing of cable conduits. Low pressure testing of cable conduits is currently still being requested by clients with the “Air” method, version LC, in accordance with DIN EN 1610. DIN EN 1610 is still valid, but somewhat outdated. Work sheet DWA-A 139-2009-12 is used to introduce changes for leakage testing according to the “Air” method. With respect to the above mentioned regulation, these changes affect designation and test duration.
The client decides which test method to use.
Method: LC, test pressure 0.1 bar (100 mbar, 10 kPa), test duration 3 min., admissible pressure drop 15 mbar (1.5 kPa)
Method: LE, test pressure 0.1 bar (100 mbar, 10 kPa), test duration 1.5 min., admissible pressure drop 15 mbar (1.5 kPa)
,231750
CodeTypeExplanation kg
231750 NDAsee above 0,00
10 | Low pressure add-on test set
This test system is an extension of the DRG 10 pressure recorder the user has available for testing cable conduits to blow up to 10 bar.

,231752
CodeTypeDesignation kg
231752 NDA 01Low pressure add-on test set 22,00
11 | Low pressure test set without battery printer
This complete test system works independently without printer. The measurement data is stored in the system and can be transferred to any PC and processed by means of an infrared interface cable forming part of the system.

,231754
CodeTypeDesignation kg
231754 NDO 01Low pressure test set without battery printer 26,00
12 | Low pressure test set with battery printer
This complete test system works independently with a battery printer. The measurement data is stored in the system and can be printed directly on the battery printer. The measurement data can also be transferred to a PC and processed by means of an infrared interface cable forming part of the system.

,231756
CodeTypeDesignation kg
231756 NDM 01Low pressure test set with battery printer 28,00
13 | Electric diaphragm pump
Electric diaphragm pump to inflate the pipelines to be tested during low pressure testing, including claw coupling 42. Max. pressure 200 mbar
Displacement at 100 mbar pressure: 160 l/min.
Displacement at 200 mbar pressure: 120 l/min.
,231760
CodeTypeEl-connection Sound level LxWxH kg
231760 MPU 120230V/95W 45 db(A) 214x185x211 6,50
14 | Shut-off bladder Mini
Shut-off bladders to lock off the pipeline to be tested. Shut-off bladders are used on the opposite side of the test location. The short dimensions of the Mini version allow space-saving installation of pipe bends also.

,231768
,231770
,231772
CodeTypeFor pipe-ID Cyl.-D Cyl.-L Total length kg
231768 SBM 7/1070-100 mm 68 mm 130 mm 175 mm 0,40
231770 SBM 8/1580-150 mm 72 mm 120 mm 170 mm 0,40
231772 SBM 12/20125-200 mm 115 mm 150 mm 195 mm 0,80
15 | Test bladder Mini
Test bladders Mini for testing and shutting off pipes for low pressure testing.

,231778
,231780
,231782
CodeTypeFor pipe-ID Cyl.-D Cyl.-L Total length kg
231778 PBM 7/1070-100 mm 68 mm 190 mm 340 mm 0,73
231780 PBM 10/15100-150 mm 90 mm 150 mm 300 mm 1,33
231782 PBM 15/20150-200 mm 145 mm 195 mm 345 mm 2,83
16 | Foot pump with double stroke
Foot pump with double stroke and safety valve 2.5 bar to inflate SBM shut-off bladders and PBM test bladders. The use of a second foot pump for the second pipe end saves considerable installation time.

,231786
CodeTypePressure kg
231786 FP 2.52,5 bar 2,40
17 | Conduit brush, steel wire
Conduit brush, steel wire, right-hand twist D 95x330/480 mm for duct int.-D 98-105 mm. For achieving a cleaning effect one brush right-hand and on brush left-hand twist must be pulled together through the duct.

Conductor-brush,duct-brush,230190
Conductor-brush,duct-brush,230200
CodeTypeSense of rotation OD Brush-L Total-L kg
230190 RDB 95 RRight-hand twist 95 mm 330 mm 480 mm 1,20
230200 RDB 95 LLeft-hand twist 95 mm 330 mm 480 mm 1,20
18 | Conduit brush, nylon
Conduit brush synthetic bristles the ext. diameter should be approx. 5-10 mm smaller than the internal diam. of the duct.

Conductor-brush,duct-brush,230328
Conductor-brush,duct-brush,230350
Conductor-brush,duct-brush,230355
Conductor-brush,duct-brush,230360
Conductor-brush,duct-brush,230370
Conductor-brush,duct-brush,230390
Conductor-brush,duct-brush,230420
Conductor-brush,duct-brush,230480
CodeTypeOD Brush-L Total-L kg
230328 RNB 5757 mm 195 mm 315 mm 0,90
230350 RNB 7777 mm 250 mm 410 mm 1,00
230355 RNB 8585 mm 250 mm 410 mm 1,20
230360 RNB 9292 mm 250 mm 410 mm 1,20
230370 RNB 9797 mm 250 mm 410 mm 1,20
230390 RNB 117117 mm 250 mm 410 mm 1,60
230420 RNB 147147 mm 250 mm 410 mm 2,10
230480 RNB 197197 mm 250 mm 410 mm 2,50
19 | Conduit calibre balls
Conduit calibre balls, Polyamide, two pcs. special short length for passing narrow duct bows. The ball-Ø should be approx. 80-85 % of the nominal internal diam. of the duct.

Conduit-calibre,duct-calibre,231250
Conduit-calibre,duct-calibre,231255
CodeTypeD mm Duct-ID Calibre-L Connection kg
231250 KGP 37/3737 40-45 2x37 mm Clipper 0,32
231255 KGP 55/5555 60-70 2x55 mm Clipper 0,44
20 | Conduit calibre
Conduit calibre of polyamide. The calibre diameter should be approx. 80-95 % of the nominal internal diameter of the duct. Please ask your customer which caliber diameter he expects.

Conduit-calibre,duct-calibre,231270
Conduit-calibre,duct-calibre,231280
Conduit-calibre,duct-calibre,231290
Conduit-calibre,duct-calibre,231310
Conduit-calibre,duct-calibre,231350
Conduit-calibre,duct-calibre,231360
Conduit-calibre,duct-calibre,231380
Conduit-calibre,duct-calibre,231400
Conduit-calibre,duct-calibre,231410
Conduit-calibre,duct-calibre,231420
Conduit-calibre,duct-calibre,231425
Conduit-calibre,duct-calibre,231430
Conduit-calibre,duct-calibre,231450
Conduit-calibre,duct-calibre,231460
Conduit-calibre,duct-calibre,231470
CodeTypeD mm Duct-ID Calibre-L Total-L kg
231270 KDP 50/3636 40-45 190 mm 190 mm 0,30
231280 KDP 63/4545 51-56 230 mm 230 mm 0,45
231290 KDP 75/5555 61-71 300 mm 300 mm 0,85
231310 KDP 90/6565 74-84 300 mm 300 mm 1,00
231350 KDP 110/8585 90-104 310 mm 310 mm 1,60
231360 KDP 110/9090 100-104 310 mm 310 mm 1,80
231380 KDP 125/9595 102-104 350 mm 350 mm 2,20
231400 KDP 125/105105 113-118 350 mm 350 mm 2,65
231410 KDP 140/115115 126-132 350 mm 350 mm 3,10
231420 KDP 150/125125 134-144 350 mm 350 mm 3,60
231425 KDP 160/130130 134-150 350 mm 350 mm 3,90
231430 KDP 160/135135 144-155 350 mm 350 mm 4,00
231450 KDP 180/150150 160-170 350 mm 350 mm 5,00
231460 KDP 200/165165 180-190 350 mm 350 mm 6,00
231470 KDP 225/185185 200-225 360 mm 360 mm 7,30